Boise Cascade BCI 5000 engineered I-joists use VERSA-LAM LVL flanges and OSB webs for floor and roof framing. Depth variants group common structural properties and code documentation for specification.

Flange Material

VERSA-LAM LVL

Flange Thickness

1-1/8 in

Web Material

OSB Exposure 1

Web Thickness

3/8 in or 7/16 in

Min End Bearing

1-1/2 in

Min Intermediate Bearing

3-1/2 in

Model Comparison

4 models
BCI 5000
Specification 9-1/2 in 11-7/8 in 14 in 16 in
Model

Shared Specifications

All models
flange_material VERSA-LAM LVL
flange_thickness 1-1/8 in
web_material OSB Exposure 1
web_thickness 3/8 in or 7/16 in
min_end_bearing 1-1/2 in
min_intermediate_bearing 3-1/2 in
icc_es ESR-1336
warranty Limited Lifetime
fire_rating 1-hour and 2-hour assemblies available
flange_width 2 in
moe 1.7E
max_cantilever 3 ft 6 in